automation服务器不能创建对象

Automation服务器不能创建对象?

automation服务器不能创建对象

文章插图

这是由于浏览器设置中把某项功能给禁止住了 , 所以才会出现这种情况 。以下是具体的解决方法:1、以IE浏览器为例,我们在右上角处点击工具 。2、点击工具后,就会出现下拉菜单,在菜单中我们找到inter选项,并且我们点击inter选项 。3、点击inter选项后,就会出现inter属性界面,在界面最上边的菜单栏中我们找见安全的菜单,选中后,我们会在最底下看见自定义级别 。4、点击进入自定义级别界面 。5、之后我们会看到如下图所示的界面,我们把其中所有的禁止都改为启动就可以了 。
遇到automation服务器不能创建对象怎么办解决方法:
1、开始-运行:regsvr32 scrrun.dll
XP系统出现“automation 服务器不能创建对象”提示怎么解决?
2、请将以下语句复制到记事本中,另存为后缀为.cmd的文件,并运行 。
echo 正在修复,这个过程可能需要几分钟,请稍候……
rundll32.exe advpack.dll /DelNodeRunDLL32 %systemroot%\System32\dacui.dll
rundll32.exe advpack.dll /DelNodeRunDLL32 %systemroot%\Catroot\icatalog.mdb
regsvr32 /s comcat.dll
regsvr32 /s asctrls.ocx
regsvr32 /s oleaut32.dll
regsvr32 /s shdocvw.dll /I
regsvr32 /s shdocvw.dll
regsvr32 /s browseui.dll
regsvr32 /s browseui.dll /I
regsvr32 /s msrating.dll
regsvr32 /s mlang.dll
regsvr32 /s hlink.dll
regsvr32 /s mshtml.dll
regsvr32 /s mshtmled.dll
regsvr32 /s urlmon.dll
regsvr32 /s plugin.ocx
regsvr32 /s sendmail.dll
regsvr32 /s mshtml.dll /i
regsvr32 /s scrobj.dll
regsvr32 /s corpol.dll
regsvr32 /s jscript.dll
regsvr32 /s msxml.dll
regsvr32 /s imgutil.dll
regsvr32 /s cryptext.dll
regsvr32 /s inseng.dll
regsvr32 /s iesetup.dll /i
regsvr32 /s cryptdlg.dll
regsvr32 /s actxprxy.dll
regsvr32 /s dispex.dll
regsvr32 /s occache.dll
regsvr32 /s iepeers.dll
regsvr32 /s urlmon.dll /i
regsvr32 /s cdfview.dll
regsvr32 /s webcheck.dll
regsvr32 /s mobsync.dll
regsvr32 /s pngfilt.dll
regsvr32 /s licmgr10.dll
regsvr32 /s hhctrl.ocx
regsvr32 /s inetcfg.dll
regsvr32 /s trialoc.dll
regsvr32 /s tdc.ocx
regsvr32 /s MSR2C.DLL
regsvr32 /s msident.dll
regsvr32 /s msieftp.dll
regsvr32 /s xmsconf.ocx
regsvr32 /s ils.dll
regsvr32 /s msoeacct.dll
regsvr32 /s wab32.dll
regsvr32 /s wabimp.dll
regsvr32 /s wabfind.dll
regsvr32 /s oemiglib.dll
regsvr32 /s directdb.dll
regsvr32 /s inetcomm.dll
regsvr32 /s msoe.dll
regsvr32 /s oeimport.dll
regsvr32 /s msdxm.ocx
regsvr32 /s dxmasf.dll
regsvr32 /s laprxy.dll
regsvr32 /s l3codecx.ax
regsvr32 /s acelpdec.ax
regsvr32 /s mpg4ds32.ax
regsvr32 /s danim.dll
regsvr32 /s Daxctle.ocx
regsvr32 /s lmrt.dll
regsvr32 /s datime.dll
regsvr32 /s dxtrans.dll
regsvr32 /s dxtmsft.dll
regsvr32 /s wshom.ocx
regsvr32 /s wshext.dll
regsvr32 /s vbscript.dll
regsvr32 /s scrrun.dll mstinit.exe /setup
regsvr32 /s msnsspc.dll /SspcCreateSspiReg
regsvr32 /s msapsspc.dll /SspcCreateSspiReg
echo.
echo.
echo 修复成功!任意键退出!
pause>nul
就是组件的注册问题,我的问题用这种方法解决了 。
3、一直用得好好的vs.net编辑器,突然有一天在我新建一个工程时 , 进行到一半时,弹出“Automation 服务器不能创建对象”,然后就停住了 。看到几个回答此类问题的,都是遇到过这个问题的朋友,他们的答案是:重装vs.net都没有作用,最后重新装操作系统才将这个问题解决 。
要我装操作系统真是要我的命,所以我一直用Copy & Paste工程文件来达到新建工程的目的 。直到有一天 , 我无意中点了vs_setup.msi 来添加vs.net的帮助文档(后来才知道应该点setup.exe来添加的) 。vs_setup.msi进行到一半,也是出错了,一看调试结果,是FileSystemObject创建失败(感谢上帝,这里的错误信息终于是友好些了) 。vs.net的错误 “Automation 服务器不能创建对象” 是不是也是这个导致的呢?
我突然想起,前几个月在网上听说可以禁止使用FileSystemObject对象,我当时都忘了怎么操作的了,反正当时一摆弄,具体怎么操作的我也忘了,从那起我也从来没有在我的程序里用过FileSystemObject了 。到google上搜索,发现禁止FileSystemObject有3种方法,第一种方法:修改注册表([HKEY_LOCAL_MACHINE\SOFTWARE\Classes\CLSID\{0D43FE01-F093-11CF-8940-00A0C9054228}\ProgID]@=“Scripting.FileSystemObject”),将FileSystemObject改成一个任意的名字,只有知道该名字的用户才可以创建该对象 。我查看注册表,该处的名字还是 Scripting.FileSystemObject 。
那么我的FSO为何不能用呢?我突然想起原来当时我用的是第二种方法,“运行Regsvr32 scrrun.dll /u,所有用户无法创建FileSystemObject” 。当时真是太狠了些 。赶快运行Regsvr32 scrrun.dll 。我试着用vs.net 创建一个工程,一阵进度提示,再也没有那个该死的“Automation 服务器不能创建对象” 。所以,遇上这类问题的朋友,仔细想想有没有动这“FileSystemObject”这个奶酪 , 应该都可以通过这个方法解决的 。否则真的要重新安装操作系统,又要重新安装vs.net喔 。
4、在控制面板中打开“用户账户”,选择其中的“更改用户登录或注销的方式”时出现“automation服务器不能创建对象”的错误提示 。(如果在执行其他操作时,出现这个错误提示,亦可按下面的方法解决,原因是一样的 。)
解决:主要是Scripting.FileSystemObject(FSO 文本文件读写)被关闭了,开启FSO功能即可,在“运行”中执行regsvr32 scrrun.dll 。
特别方法:在“运行”中执行regsvr32 shimgvw.dll 。
5、不用重新安装操作系统和vs.net,但有些脚本需要微软的 MSXML 控件才能进入 。当使用 IE 5 以上版本的缺省安全模式时,会提示是否接受 MSXML 控件,如果接受,MSXML 将自动安装到您的机器上(得等上几分钟) 。如果自动安装不成功,可以自行下载和安装 MSXML 3.0 。如果安装 MSXML 3 后仍然出现“Automation 服务器不能创建对象”错误,是因为您的机器禁止了所有的ActiveX,一般将 IE 的安全模式设为“中”即可 。
6、我的机器用了上面的方法没有解决问题,用下面的方法解决了问题,大家不妨可以试试:打开Internet Explorer “工具”菜单栏中的“选项”一栏,单击“安全”栏中的“自定义级别”选项卡 , 将第三项“对没有标记为安全的activex控件进行初始化和脚本运行”设置成“启用”即可 。
以上便是在使用XP系统的时候碰到“automation服务器不能创建对象”提示的解决办法,有些用户可能被这个问题困扰已久,现在按照上面介绍的几种方法来解决就可以 。

最近在访问网站时经常出现“Automation 服务器不能创建对象”的错误提示框,请问这个问题该怎么解决?访问某些网站的时候,如果出现“Automation 服务器不能创建对象”的错误提示框,则表明网页内的对象需要scrrun.dll库文件的支持,可以尝试下面的方法:

点击“开始→运行”并输入“regsvr32 scrrun.dll” 。

不用重新安装操作系统和vs.net,但有些脚本需要微软的 MSXML 控件才能进入 。当使用 IE 5 以上版本的缺省安全模式时,会提示是否接受 MSXML 控件,如果接受 , MSXML 将自动安装到您的机器上(得等上几分钟) 。如果自动安装不成功,可以自行下载和安装 MSXML 3.0 。如果安装 MSXML 3 后仍然出现“Automation 服务器不能创建对象”错误,是因为您的机器禁止了所有的ActiveX,一般将 IE 的安全模式设为“中”即可 。

实例:在控制面板中打开“用户账户”,选择其中的“更改用户登录或注销的方式”时出现“automation服务器不能创建对象”的错误提示 。(如果在执行其他操作时,出现这个错误提示 , 亦可按下面的方法解决,原因是一样的 。)

解决:主要是Scripting.FileSystemObject(FSO 文本文件读写)被关闭了,开启FSO功能即可,在“运行”中执行regsvr32 scrrun.dll 。

附:如果Javascript脚本中报这个错误是因为IE的安全设置不允许运行未标记为安全的activeX控件 更改IE的安全设置,把相应的选项打开即可 。

打印机打开失败Automation服务器不能创建对象是什么意思?一:主要是Scripting.FileSystemObject (FSO 文本文件读写)被关闭了,开启FSO功能即可,在“运行”中执行regsvr32 scrrun.dll二:如果javascript脚本中报这个错误是因为IE的安全设置不允许运行未标记为安全的activeX控件 更改IE的安全设置,把相应的选项打开即可 。有时用上面“解决”中所提的方法不是100%成功的 , 因为毕竟导致同样现象的原因并不是只会有一个,这个亦是一个思路 。如果是在安装某个软件后出现这种问题 , 可卸载该软件或重装一下!

Automation 服务器不能创建对象
automation服务器不能创建对象

文章插图

1,打开IE浏览器,鼠标点击“工具”菜单,点击后将会带出多个子菜单,如图所示:2,在弹出的下拉菜单中,选择“Internet 选项(O)”选项 , 选择后系统自动弹出一个名为“Internet 选项”的对话框,如图所示:3,在弹出的对话中,在选择区域中有四个选项,分别为“Internet”、“本地Intranet”、“受信任的站点”和“受限制的站点” 。在此我们选择“Internet”区域,选择后我们可以看到窗口下方有个名称为“自定义级别”的按钮,选择点击改按钮,开始对该区域的安全级别进行设置 。如图所示:4、接上一步骤,点击“自定义级别”按钮后,系统弹出一个安全设置对话框(这里包含浏览器所有的安全设置相关的选项),如图所示:5 , 在打开的安全设置对话中,在设置内容里面 , 我们找到如下图所示的安全设置选项,将这些选项的设置都改为“启用”状态,如图所示:6 , 要启用的内容选择完成后,我们需要进行安全设置内容的保存,点击“确定”按钮 。点击按钮后 , 系统会有个当前设置可能会存在风险是否要进行修改的确认提示 , 我们直接点击确定修改即可 。如图所示:7,以上设置完成后,然后再在“Internet选项”对话中点击“确定”按钮,这样我们就完成了浏览器安全设置的更改 。更改完成后,重启浏览器,然后再进行相应的网站或系统的操作就可了 。如图所示:
打印发票提示AUTOMATION不能创建对象?(1) 打印发票时打印机没反应
答:打印机未添加,点击打印设置添加一个打印机提交即可,具体操作如下:
①点击页面右上方“打印设置”,点击“增加” ,参照打印机类型:在下拉菜单中选择本企业实际使用的打印机名称 , 若打印机类型不在选择列表中,可以任意选择一款型号 。
②选择发票种类:在下拉菜单中选择本企业需要打印的发票种类
③调整边距:纳税人可根据不同发票输入数值 , 调整套打的位置(建议纳税人在第一次打印前 , 设置值为0,并先用普通A4纸张测试发票套打的位置)
④启用:自动显示为启用状态
⑤完成上述设置后,点击“保存”
(2)打印时提示下载“下载电子发票打印控件”
答:说明尚未安装网络发票打印控件注册表
请找到“下载”里 “网络发票打印控件注册表添加”安装运行后,出现,必须双击这个图标,按系统提示操作完成后重启电脑即可进行发票的打?。?

电脑提示automation服务器不能创建对象怎么办点击开始 , 找到运行,点击它 。如下图:

在打开的界面中,输入:regedit.exe,然后安确定 。(这个呢就是我们通常说的打开注册表,其实打开注册表的方法有很多,只不过我们常用这一种)

好了,现在找到红框所示的位置,点击打开它 。

接下来,再找到下图所示的内容,双击打开 。

现在呢找到Microsoft项,再打开它 。

再往下找,找到Internet Explorer项,再打开它 。

打开后,找到第二项,如下图所示,再打开它 。

然后,找到红框内的那一条,点击它 。

好了,现在右边出现了如下图所示的两条 。

选择第二条,双击它 。在出现界面中,把红框内的数值改成0 , 按确定键,直接关闭注册表 。现在你再去打印看看 。

当然是可以打印喽,这个方法呢,不是我自己想到的,也不知道为什么要这样改,网上呢也有人介绍,只不过在我这里呢 , 有图有真相,一目了然 。

Automation server can't create object, AUTOMATION服务器无法创建对象方法一:
开始-运行:regsvr32 scrrun.dll


方法二:
请将以下语句复制到记事本中,另存为后缀为.cmd的文件 , 并运行 。当然在命令行下一句句运行也没问题 。
echo 正在修复 , 这个过程可能需要几分钟,请稍候……
rundll32.exe advpack.dll /DelNodeRunDLL32 %systemroot%\System32\dacui.dll
rundll32.exe advpack.dll /DelNodeRunDLL32 %systemroot%\Catroot\icatalog.mdb
regsvr32 /s comcat.dll
regsvr32 /s asctrls.ocx
regsvr32 /s oleaut32.dll
regsvr32 /s shdocvw.dll /I
regsvr32 /s shdocvw.dll
regsvr32 /s browseui.dll
regsvr32 /s browseui.dll /I
regsvr32 /s msrating.dll
regsvr32 /s mlang.dll
regsvr32 /s hlink.dll
regsvr32 /s mshtml.dll
regsvr32 /s mshtmled.dll
regsvr32 /s urlmon.dll
regsvr32 /s plugin.ocx
regsvr32 /s sendmail.dll
regsvr32 /s mshtml.dll /i
regsvr32 /s scrobj.dll
regsvr32 /s corpol.dll
regsvr32 /s jscript.dll
regsvr32 /s msxml.dll
regsvr32 /s imgutil.dll
regsvr32 /s cryptext.dll
regsvr32 /s inseng.dll
regsvr32 /s iesetup.dll /i
regsvr32 /s cryptdlg.dll
regsvr32 /s actxprxy.dll
regsvr32 /s dispex.dll
regsvr32 /s occache.dll
regsvr32 /s iepeers.dll
regsvr32 /s urlmon.dll /i
regsvr32 /s cdfview.dll
regsvr32 /s webcheck.dll
regsvr32 /s mobsync.dll
regsvr32 /s pngfilt.dll
regsvr32 /s licmgr10.dll
regsvr32 /s hhctrl.ocx
regsvr32 /s inetcfg.dll
regsvr32 /s trialoc.dll
regsvr32 /s tdc.ocx
regsvr32 /s MSR2C.DLL
regsvr32 /s msident.dll
regsvr32 /s msieftp.dll
regsvr32 /s xmsconf.ocx
regsvr32 /s ils.dll
regsvr32 /s msoeacct.dll
regsvr32 /s wab32.dll
regsvr32 /s wabimp.dll
regsvr32 /s wabfind.dll
regsvr32 /s oemiglib.dll
regsvr32 /s directdb.dll
regsvr32 /s inetcomm.dll
regsvr32 /s msoe.dll
regsvr32 /s oeimport.dll
regsvr32 /s msdxm.ocx
regsvr32 /s dxmasf.dll
regsvr32 /s laprxy.dll
regsvr32 /s l3codecx.ax
regsvr32 /s acelpdec.ax
regsvr32 /s mpg4ds32.ax
regsvr32 /s danim.dll
regsvr32 /s Daxctle.ocx
regsvr32 /s lmrt.dll
regsvr32 /s datime.dll
regsvr32 /s dxtrans.dll
regsvr32 /s dxtmsft.dll
regsvr32 /s wshom.ocx
regsvr32 /s wshext.dll
regsvr32 /s vbscript.dll
regsvr32 /s scrrun.dll mstinit.exe /setup
regsvr32 /s msnsspc.dll /SspcCreateSspiReg
regsvr32 /s msapsspc.dll /SspcCreateSspiReg
echo.
echo.
echo 修复成功!任意键退出!
pause>nul

如果是组件的注册问题,用这种方法解决了 。

方法三:
我的机器用了上面的方法没有解决问题,用下面的方法解决了问题,大家不妨可以试试:打开Internet Explorer “工具”菜单栏中的“选项”一栏,单击“安全”栏中的“自定义级别”选项卡 , 将第三项“对没有标记为安全的activex控件进行初始化和脚本运行”设置成“启用”即可 。

Excel导入ie浏览器是出现读取数据失败Error: Automation 服务器不能创建对象【automation服务器不能创建对象】Internet 选项→安全→自定义级别→对未标记为可安全执行脚本的...→启用

遇到automation服务器不能创建对象怎么办解决方法:
1、具体情况是这样的 , 当把设置好,按打印的时候,总会弹出一个:automation服务器不能创建对象“这个窗口提示 。
2、其实在网上的办法综合起来也就是四种,与其说是四种,不如说是四个步骤,根据你所遇到的情况不同,选择其中的一种就可以解决了 。在打印时提示 , 像接下来这样操作就可以了 。找到IE浏览器,打开它 。
3、输入网站开票系统 。

4、找到设置里面的,internet选项,打开它 , 它就会弹出一个窗口 。
5、弹出的界面,点击其中的安全选项卡 。
6、接下来打开其中的,自定义级别 。

7、拖动右边的滚动条,找到如下面图所示的几项,全部选择成启用 , 按确定 。

电脑IE浏览器提示“Automation服务器不能创建对象”怎么办1、打开IE浏览器,点击“工具”菜单——Internet选项;

2、在“安全”选项卡下选中“Internet”区域,再点击“自定义级别”;

3、在打开的安全设置窗口中 , 找到如下图的四个选项:
·对标记为可安全执行脚本的 ActiveX 控件执行脚本
·对未标记为可安全执行脚本的 ActiveX 控件初始化并执行

·运行 ActiveX 控件和插件

·仅允许经过批准的域在未经提示的情况下使用 ActiveX

将这些选项全部选择“启用”状态;
4、修改完后点击确定,弹出确认窗口,点击是;


5、以上设置完成后,再在“Internet选项”窗口点击“确定”按钮,这样我们就完成了浏览器的更改 。

IE浏览器出现“Automation 服务器不能创建对象”怎么办你好!具体如下:

IE浏览器打开,出现automation服务器不能创建对象1. 点击菜单“工具”—“Internet选项”—安全, 点击“受信任的站点”—“站点”2. 将网址输入,然后点击”添加”,点击”确定”3.点击”受信任的站点”,点击”自定义级别”4. “ActiveX 控件和插件” ,按图设置点击”确定”
电脑IE浏览器提示“Automation服务器不能创建对象”怎么办打开IE浏览器,鼠标点击“工具”菜单,点击后将会带出多个子菜单,如图所示:

在弹出的下拉菜单中,选择“Internet 选项(O)”选项,选择后系统自动弹出一个名为“Internet 选项”的对话框,如图所示:


在弹出的对话中,在选择区域中有四个选项,分别为“Internet”、“本地Intranet”、“受信任的站点”和“受限制的站点” 。在此我们选择“Internet”区域,选择后我们可以看到窗口下方有个名称为“自定义级别”的按钮 , 选择点击改按钮 , 开始对该区域的安全级别进行设置 。

接上一步骤,点击“自定义级别”按钮后 , 系统弹出一个安全设置对话框(这里包含浏览器所有的安全设置相关的选项),

在打开的安全设置对话中,在设置内容里面,我们找到如下图所示的安全设置选项,将这些选项的设置都改为“启用”状态 , 



要启用的内容选择完成后,我们需要进行安全设置内容的保存,点击“确定”按钮 。点击按钮后,系统会有个当前设置可能会存在风险是否要进行修改的确认提示,我们直接点击确定修改即可 。

以上设置完成后,然后再在“Internet选项”对话中点击“确定”按钮,这样我们就完成了浏览器安全设置的更改 。
更改完成后,重启浏览器,然后再进行相应的网站或系统的操作就可了 。

打印机出现automation服务器不能创建对象怎么办解决方法:
1、具体情况是这样的,当把设置好,按打印的时候,总会弹出一个:automation服务器不能创建对象“这个窗口提示 。
2、其实在网上的办法综合起来也就是四种,与其说是四种,不如说是四个步骤,根据你所遇到的情况不同,选择其中的一种就可以解决了 。在打印时提示,像接下来这样操作就可以了 。找到IE浏览器,打开它 。
3、输入网站开票系统 。

4、找到设置里面的,internet选项,打开它 , 它就会弹出一个窗口 。
5、弹出的界面 , 点击其中的安全选项卡 。
6、接下来打开其中的,自定义级别 。

7、拖动右边的滚动条,找到如下面图所示的几项,全部选择成启用,按确定 。

电脑IE浏览器提示“Automation服务器不能创建对象”怎么办“automation服务器不能创建对象”的问题的解决方案大全

本人工作中的应用系统都是jsp的,大量javascript程序 , 一旦出“automation服务器不能创建对象”问题,大量报表及查询无法保存,苦思冥

想、千尝万试,终于将其搞定 , 现将相关方案与大家共享 。
1、如果是Scripting.FileSystemObject (FSO 文本文件读写)被关闭了 , 开启FSO功能即可,在“运行”中执行regsvr32 scrrun.dll即可

2、安全模式设置成“中”,如果javascript脚本中报这个错误,还应将IE的安全设置“不允许运行未标记为安全的activeX控件”启用即可 。

注意如果您将相应的网站设成“受信任的站点”,必须对“受信任的站点”进行相应的IE安全设置 , 此时如果对“Internet”IE设置将是徒劳

的 。

3、有些脚本需要微软的 MSXML 控件才能进入 。当使用 IE 5 以上版本的缺省安全模式时 , 会提示是否接受 MSXML 控件,如果接受,MSXML 将

自动安装到您的机器上(得等上几分钟) 。如果自动安装不成功,可以自行下载和安装 MSXML 3.0 SP7 。有时是由于msxml 3服务被关掉了,使用

regsvr32 msxml3.dll即可

4、用上面方法基本上能决问题 。如果是在安装某个软件后出现这种问题,可尝度卸载该软件或重装一下!

Automation服务器不能创建对象对话框组件没有正确安装看到网上的文章真是一大抄,解决的办法都一样,但就唯独缺少第4种方法,也就是我最后才解决的办法 。下面就4种方法一一说明:
1、在“运行”中执行regsvr32 scrrun.dll即可
2、安全模式设置成“中”,如果java脚本中报这个错误,将IE的安全设置“不允许运行未标记为安全的activeX控件”启用 。
注意如果您将该的网站设成“受信任的站点” , 则必须对点击选择“受信任的站点”的图标 自定义安全级别,此时的设置的安全级别则只对“受信任站点”有作用 。

办公系统登陆后提示“服务器不能创建对象”是什么原因???访问某些网站的时候 , 如果出现“Automation 服务器不能创建对象”的错误提示框,则表明网页内的对象需要scrrun.dll库文件的支持,可以尝试下面的方法: 点击“开始→运行”并输入“regsvr32 scrrun.dll” 。不用重新安装操作系统和vs.net,但有些脚本需...

打开用户帐户时,出现Automation 服务器不能创建对象,这是怎么回事?是不是打开控制面板里的用户帐户时出的问题?。?br>给你说几个方法解决 。
第1种方法:
这种情况需指定正确的模块,而模块信息是在注册表的某键值中指定的 , 请安装下面步骤来操作:-1、单击『开始』菜单中的“运行”并键入“regedit”后单击“确定”启动“注册表编辑器”; 2、在“注册表编辑器”中展开至HKEY_CLASSES_ROOT\CLSID\{13709620-C279-11CE-A49E-444553540000}\InProcServer32j(/
3、在右侧中的“(默认)”键值确保键值内容为
%SystemRoot%\system32\SHELL32.dll


第2种方法:
1、单击『开始』菜单中的“运行”并键入“regedit”后单击“确定”按钮启动“注册表编辑器”;
2、在“注册表编辑器”中展开至
HKEY_CLASSES_ROOT\CLSID\{72C24DD5-D70A-438B-8A42-98424B88AFB8}\InProcServer32
3、在右侧中的“(默认)”键值确保键值内容为
C:\Windows\system32\wshom.ocx
(如果你的操作系统并非在C盘,请根据实际情况操作 。)


以上2件事做完后再:
运行中输入如下:
regsvr32 jscript.dll
regsvr32 vbscript.dll
修正后重启计算机 。

单击“开始/运行” , 输入“rundll32 netplwiz.dll,UsersRunDll” , 按回车键后弹出“用户帐户”窗口,看清楚,这可跟“控制面板”中打开的“用户账户”面板窗口不同哦!然后取消选定“要使用本机 , 用户必须输入用户名和密码”选项,单击确定 , 在弹出的对话框中输入你想让电脑每次自动登录的账户和密码即可

开始——运行 , 分别输入下列命令,修复一下

regsvr32 nusrmgr.cpl
regsvr32 mshtml.dll
regsvr32 jscript.dll
regsvr32 /i shdocvw.dll
regsvr32 sxs.dll

1.你可以右击我的电脑(不是快捷方式),选择“管理”里面有本地用户和组 , 可以进行帐户操作
2.工具-选项-查看,选择不缓存缩略图,然后开始-搜索“Thumbs.db”全部文件和文件夹(包括隐藏的文件、文件夹),这个是缩略图的故障,删除了全部的文件就好

权限的问题
在开始菜单下按运行 输入CMD打开
输入内容
net localgroup administrators 这里填你要提升权限的用户名 /add
这样就可以了

Win7系统下IE网页报错“Automation 服务器不能创建对象”怎么办“automation服务器不能创建对象”的问题的解决方案大全 本人工作中的应用系统都是jsp的,大量javascript程序,一旦出“automation服务器不能创建对象”问题,大量报表及查询无法保存 , 苦思冥 想、千尝万试,终于将其搞定 , 现将相关方案与大家共享 。1、如果是Scripting.FileSystemObject (FSO 文本文件读写)被关闭了,开启FSO功能即可,在“运行”中执行regsvr32 scrrun.dll即可 2、安全模式设置成“中”,如果javascript脚本中报这个错误,还应将IE的安全设置“不允许运行未标记为安全的activeX控件”启用即可 。注意如果您将相应的网站设成“受信任的站点”,必须对“受信任的站点”进行相应的IE安全设置,此时如果对“Internet”IE设置将是徒劳 的 。3、有些脚本需要微软的 MSXML 控件才能进入 。当使用 IE 5 以上版本的缺省安全模式时,会提示是否接受 MSXML 控件,如果接受 , MSXML 将 自动安装到您的机器上(得等上几分钟) 。如果自动安装不成功 , 可以自行下载和安装 MSXML 3.0 SP7 。有时是由于msxml 3服务被关掉了,使用 regsvr32 msxml3.dll即可 4、用上面方法基本上能决问题 。如果是在安装某个软件后出现这种问题,可尝度卸载该软件或重装一下!参考资料:忘记了.... - 3-